MQS TechnologiesContact us

MQIR 225 X-Ray Irradiator

Lab-Grade X-ray Irradiation. Precise Dose Control. Built for Safety & Speed.

MQIR Series X-ray Irradiators are designed to irradiate samples to the desired energy and dose in a standard laboratory environment.

Up to 225 kVUp to 4500 WAERB-guideline shieldingStainless-steel chamber
MQIR 225 X-ray irradiator cabinet with stack light, control screens, warning label and blue base on castors
Up to 225 kV
Nominal energy
Up to 4500 W
Maximum power
≥ 12 Gy/min
Dose output, unfiltered (225 kV, SSD 30 cm)
≤ 0.1 mR/hr
Certified low leakage

MQIR 225 combines a high-power X-ray generator and tube to deliver consistent dose output at a set energy with stability and accuracy comparable to industry-leading irradiators. The system is housed in a shielded cabinet meeting AERB safety standards, with adequate cooling to operate continuously for long duration. The stainless-steel irradiation chamber measures 60 cm (H) × 42 cm (W) × 43 cm (D) and includes an adjustable sample shelf to vary SSD.

Key Benefits

01

High Energy & Power for Reliable Dose Delivery

Up to 225 kV energy and 4500 W maximum power for lab irradiation workflows.

02

Precise Dose Control

Optional internal dosimeter supports exact dose measurement and control.

03

Configurable Beam Shaping

Interchangeable beam conditioning filters along with adjustable beam collimator for controlled exposure field.

04

User-Friendly Operation & Repeatability

GUI-based touch screen, warm-up automation, and unlimited preset memories for multi-user labs.

05

Safety-First, AERB-Ready Shielding

Designed per AERB guidelines with certified low leakage ≤ 0.1 mR/hr and steel/lead/steel sandwich construction.

Solution Highlights

MQIR 225 X-ray irradiator cabinet with lettered callouts on the touchscreen control panel and the shielded cabinet

Dose Output

At 225 kV and SSD 30 cm.

≥ 12Gy/min

Unfiltered, at 225 kV and SSD 30 cm.

Technical Information

System Specifications

ParameterSpecification
Nominal EnergyUp to 225 kV
Maximum PowerUp to 4500 W
Focal Spot (EN 12543)Small 1.2 mm, Large 5.5 mm
Inherent Filtration2.0 mm Be
Radiation Coverage40°
Irradiation Chamber60 (H) × 42 (W) × 43 (D) cm, stainless steel
Dose Output (225 kV, SSD 30 cm)≥ 12 Gy/min (unfiltered), ≥ 6 Gy/min (filtered)
Exposure Settings5–225 kV, 0.1–30 mA, 1–99999 sec
Power Requirement220 VAC ±10%, 50/60 Hz, single phase
Safety/ShieldingAERB-guideline design; low leakage ≤ 0.1 mR/hr; steel/lead/steel

Accessories & Options

  • Inbuilt CCTV for monitoring the specimen
  • Programmable motorized rotator shelf
  • Automatic adjustable collimator + additional circular collimators
  • Restrainers/shielders for tumor targeting, autoclavable mouse disk, mouse pie cage
  • Digital imaging system (optional)

Need irradiators of other energies (20–450 kV) or chambers of custom sizes?

Talk to an Expert
Get in touch

Tell us what you need to inspect

Share your part, material and defect type — our engineers will recommend the right MQS system.